Relay Pack for Line-voltage FCU: 90 to 277 VAC 50/60 Hz, 2/4 Pipes, SER models, 4 Inputs, On-Off, 1 H/C output, 1 cool output, 3 fan outputs
Zoom image

Relay Pack for Line-voltage FCU: 90 to 277 VAC 50/60 Hz, 2/4 Pipes, SER models, 4 Inputs, On-Off, 1 H/C output, 1 cool output, 3 fan outputs


Not rated yet

Relay Pack for Line-voltage FCU: 90 to 277 VAC 50/60 Hz, 2/4 Pipes, SER models, 4 Inputs, On-Off, 1 H/C output, 1 cool output, 3 fan outputs

  • $84.96
Qty:  
  • Weight
    0.75 lbs
  • SKU
    SC3504E5045

RELPK SER 1H/1C 1C 4IN3FO

Accessory Type Relay Pack
Application Low Voltage Fan Coil
Brand Schneider Electric
By Schneider Yes
Communication Stand-Alone (Network Ready)
Dehumidification Setpoint Range 30 to 95 RH
Dimensions Depth 33 mm (1.3 in)
Dimensions Height 122 mm (4.80 in)
Dimensions Weight 0.75 lb (0.34 kg)
Dimensions Width 80 mm (3.15 in)
Humidity Control No
Humidity Sensor and Calibration Single point calibrated bulk polymer type sensor
Humidity Sensor Precision Reading range from 10 to 90% RH non-condensing. 10 to 20% precision: 10%; 20% to 80% precision: 5%; 80% to 90% precision: 10%
Humidity Sensor Stability Less than 1.0 yearly, typical drift
Operating Humidity 0 to 95 RH non-condensing
Operating Temperature 0 to 50 C (32 to 122 F)
Power Input Tolerance Plus or minus 10%
Power Input Voltage 7 VDC
Setpoint Range Cooling 12 to 37.5 C (54 to 100F)
Setpoint Range Heating 4.5 to 32 C (40 to 90 F)
Standards EMC EMC Directive 2004/108/EC
Standards EMC FCC 15 Subpart B
Standards EMC ICES-003
Standards EMC IEC 61326-1:2005
Standards Safety CAN.SSA C22.2.NO.24
Standards Safety EN 60730-2-9
Standards Safety LVD Directive 2006/95/EC
Standards Safety UL 873
Storage Humidity 0 to 95 RH non-condensing
Storage Temperature -30 to 50 C (-22 to 122 F)
Temperature Accuracy Plus or minus 0.5 C ( Plus or minus 0.9 F) at 21 C (70 F) typical calibrated
Temperature Display Range -40 to 50 C (-40 to 122 F)
Temperature Proportional Band Cooling and Heating default 1.8 C (3.2 F)
Temperature Sensor Onboard Local 10 K NTC type 2 thermistor
Temperature Sensor Resolution Plus or Minus 0.1 C (Plus or Minus 0.2 F)
Voltage Cool Line Yellow Wire, 5A maximum
Voltage Fan Line Brown, Blue, Red Wires 1/2 HP or 13A maximum
Voltage Main Heat Orange Wire, 10A maximum
Wire Gauge 14 gauge maximum, 22 gauge recommended